How they are built, how they are calculated and selected, how door lift types differ, how long they last and how to replace them safely. A detailed guide with calculation examples.
Author: E. V. Fefelov, developer of the TORSMASTER 500 winder
01Why a door needs springs
The door leaf of a residential 2.5×2.5 m sectional door weighs 60–90 kg; that of a 5×5 m industrial door weighs 300–450 kg. Such a weight cannot be lifted by hand or by a small operator, so the weight of the leaf is counterbalanced by springs. The operator or the person only overcomes friction and inertia.
A properly balanced door stays put in any position: half a metre above the floor, halfway, almost at the ceiling. It neither rises by itself nor drops. This is the main criterion of correctly selected and wound springs.
Torsion springs work in torsion. They are mounted on a shaft above the opening: one end of the spring is fixed to a bracket, the other to the shaft. Cable drums sit at the ends of the shaft; they wind up the cables that run to the bottom corners of the leaf. When the door is closed, the springs are wound up and hold the weight of the leaf through the drums. When the door opens, the springs unwind and release the stored energy.
Fig. 1. Torsion mechanism of a standard-lift door with two springs, viewed from inside the building. The stationary plugs are bolted to brackets near the ends of the shaft; the winding plugs face the center. The left and right springs are wound in opposite directions: as they unwind, both lift the door.
Besides torsion springs, there are extension springs. European manufacturers mount them vertically, in the side columns along the vertical tracks: this is how DoorHan RSD01 BIW garage doors, Alutech Prestige with extension springs and Hörmann with Z hardware (Zugfeder) are built. The cable runs from the bottom corner of the leaf upward, over a pulley at the top of the column, and pulls the spring. To make a break less dangerous, the springs are made as a “spring within a spring” — inner and outer. Horizontal mounting, above the horizontal tracks, is also found — mainly on American and older doors.
Extension springs are used only on light garage doors, but in return they need almost no headroom (from 100 mm). DoorHan rates such a mechanism for 15,000 cycles. Heavy and industrial doors are balanced only with torsion springs, and the rest of this article is about them.
02What a torsion assembly consists of
A spring is almost always supplied assembled with its plugs. The assembly includes:
Spring — a helical spring made of spring wire, close-wound, with no gaps between the coils.
Stationary plug — screwed into one end of the spring and bolted to the center (or end) bracket. It keeps this end from turning.
Winding plug — screwed into the other end. It has holes for the winding bars used to wind the spring, and set screws (usually two) that clamp the plug to the shaft.
Plastic insert (core) — in springs with an inside diameter of 95 and 152 mm. A long large-diameter spring sags under its own weight and rubs against the shaft; the insert keeps it on the axis.
The plugs have a helical groove into which the end coils fit. The fit is tight, so removing a plug from a spring without special techniques is difficult. Each door manufacturer has its own plugs: DoorHan, Alutech and Hörmann springs are not directly interchangeable, even if the wire size and diameter match.
Other parts of the mechanism work around the spring: the shaft (most often a hollow Ø25.4 mm shaft with a keyway; some manufacturers use a larger-diameter tube), cable drums at the ends of the shaft, cables, end supports with bearings and a spring break safety device. The latter locks the shaft if a spring breaks and keeps the leaf from falling. European door standards (EN 13241, EN 12604) require such protection, so it is fitted to modern doors almost always.
Fig. 2. Spring, exploded view. The end coils fit into the helical grooves of the plugs. The insert is shown dashed inside the spring.
03Spring dimensions and winding direction
A spring is described by four parameters. They are used to order it and to check whether a replacement will fit.
Inside diameter (ID). Standard series: 45, 50, 67, 95 and 152 mm (Hörmann industrial doors also use 142 and 182 mm). The larger the diameter with the same wire, the softer the spring and the more turns it can take.
Wire diameter (d) — usually from 5.0 to 11.5 mm in 0.5 mm steps (up to 12 mm and more on heavy doors). The rate grows as d⁴: 8 mm wire instead of 7 makes the spring 70% stiffer.
Length (L) in the free, unwound state. The length determines the number of active coils: the longer the spring, the softer it is and the lower the stress in the metal.
Winding direction: left-hand (L) or right-hand (R).
Fig. 3. Main dimensions. ID = OD − 2d. Calculations use the mean diameter Dm = ID + d — the axis of the wire runs along it.
Left-hand and right-hand winding
Springs on the same shaft are wound up in opposite directions, so the two springs of a pair have different winding. A right-hand wind runs like the thread of an ordinary bolt, a left-hand wind like a bolt with a left-hand thread. If you lay the spring horizontally and look at the front coils, on a right-hand spring they slant like “\”, on a left-hand spring like “/”.
Manufacturers mark the winding with color. At DoorHan and Alutech, a red stripe or a red plug means left-hand wound, blue or black means right-hand wound. Which winding goes on which side depends on where the stationary plugs are fixed. If they are near the ends of the shaft and the winding plugs face the center, as in Fig. 1, then, viewed from inside the building, the left-hand wound spring is on the left and the right-hand wound spring on the right. If the stationary plugs are bolted to the center bracket, it is the other way round. Either way, the spring must unwind as the door opens. Before installation, check this against the instructions for the specific door: a mixed-up spring will not wind up when tensioned, but unwind and lose its shape.
Fig. 4. Winding direction and color stripe. The stripe is applied at the factory along the whole spring; when the spring is wound, it twists into a helix and helps count the turns (see section 9).
04How springs are calculated
The door manufacturer calculates the springs at the design stage, with its own software and its own tables: they incorporate its drums, shafts, tracks and plugs. The door documentation or the data plate gives the spring sizes and the number of winding turns. But the calculation principle is common, and it is useful to understand.
What is taken into account
Door leaf weight. The main input value. It depends on the area, panel thickness (40 or 45 mm), insulation, glazing and a built-in wicket door. A wicket door and windows can add 15–30 kg.
Opening height. Determines how much cable has to be wound onto the drum, and therefore how many turns the spring will make.
Drum type. Its winding diameter sets the lever arm on which the leaf weight acts on the shaft.
Lift type. Standard, low headroom, high lift, vertical, roof-pitch. It determines how the load changes along the door travel and which drum is needed (section 5).
Required cycle life — from 10,000 to 100,000 cycles and more. The higher the cycle life, the lower the permissible stress in the metal, and the thicker and longer the springs.
Number of springs and their position on the shaft. One, two or more springs; heavy doors get four springs, sometimes on two shafts, or a “spring within a spring” (for example, 95 inside 152).
Step 1. Torque from the weight
The leaf pulls the cables down. On the shaft this produces a torque equal to the weight multiplied by the winding radius of the drum:
M = m · g · rd
Example: an 80 kg leaf, a standard-lift drum with a winding diameter of 102 mm (radius 0.051 m). M = 80 · 9.81 · 0.051 ≈ 40 N·m. With two springs, each holds 20 N·m.
Step 2. How many turns
To raise the leaf by the height of the opening, the drum must wind up a cable length of H. One revolution of the drum winds π·Dd. Pre-tension is added to this so that the cables stay taut in the open position:
N = H / (π · Dd) + Npre
For a 2500 mm opening: 2500 / (3.14 · 102) ≈ 7.8 turns, plus half a turn — about 8.3 turns. This is the figure given in the door documentation as the number of winding turns.
Step 3. Spring rate and length
The spring is wound N turns and must deliver torque M. So its rate per turn is c = M / N = 40 / 8.3 ≈ 4.8 N·m per turn. The rate of a torsion spring depends on the material and dimensions:
c = 2π · E · d⁴ / (64 · Dm · n) [N·mm per turn]
Here E ≈ 206,000 N/mm² is the elastic modulus of steel, Dm = ID + d, n is the number of active coils. From this, n is found, and the spring length is calculated as (n + allowance for the coils in the plugs) · d. About 8–10 coils of each spring go into the plugs and do not work.
Step 4. Stress and cycle life
When the spring is wound, the wire works in bending. The stress in it:
σ ≈ 32 · M / (π · d³) [N/mm²]
It is the stress that determines how many cycles the spring will last. A spring for the same torque can be selected with different combinations of d and ID, and all of them will balance the door correctly. They will differ in cycle life, length, weight and price. The same example, 80 kg on a single spring, 8.3 turns:
Wire × ID
Length
Stress
Weight
Cycle life, approx.
7.0 × 67 mm
≈ 1015 mm
≈ 1190 N/mm²
≈ 10 kg
≈ 25,000 cycles
7.5 × 67 mm
≈ 1400 mm
≈ 970 N/mm²
≈ 15 kg
≈ 50,000 cycles
8.0 × 95 mm
≈ 1410 mm
≈ 800 N/mm²
≈ 22 kg
≈ 100,000 cycles
You can see how the cost of cycle life grows: four times more cycles means twice as much metal and a 40% longer spring. A long spring may not fit on the shaft between the bracket and the drum. Then two springs are used, or a larger diameter, or a “spring within a spring”.
The cycle life figures in the table are estimates based on stress, not data from a specific manufacturer. Each plant has its own fatigue curves, depending on the wire and the technology.
Why the spring unwinds evenly and the door still balances. The spring torque drops linearly with each turn. With a standard lift, the load also drops: the sections one after another move onto the horizontal tracks and stop hanging on the cables. The two lines almost coincide over the whole travel (fig. 5, left). With a vertical lift, the leaf weighs the same over the whole travel, and the spring has to be matched to the load with a conical drum (fig. 5, right).
Standard lift, regular drum
Vertical lift
spring torquetorque from leaf weightsame with a cylindrical drum
Fig. 5. Torque on the shaft along the opening travel, as a fraction of the torque in the closed position. A diagram to explain the principle, not a measurement. Right: with a cylindrical drum, the leaf weight (dashed) stays the same toward the end of travel while the spring weakens, and the door cannot be opened fully. A conical drum reduces the lever arm as the cable winds on and evens out the torques.
05Door lift types
The lift is the shape of the tracks along which the leaf moves under the ceiling. It is selected by the headroom — the distance from the top of the opening to the ceiling or to the lowest beam, pipe or light fixture above the door's path. The lift type determines where the shaft with the springs is located, which drum is needed and how many turns the spring makes.
trackleaf in closed positionshaft with springsextension spring (in side column)H — opening height, HR — headroom
Fig. 6. Track types, side view, based on DoorHan and Alutech installation drawings. The closed leaf sits tight against the lintel and overlaps it above the opening; the top section is then already resting with its rollers on the track radius. Below the drawings is the minimum headroom per the DoorHan technical solutions catalog (ISD industrial doors) or per the Alutech technical catalog if DoorHan has no such type. Figures for other series are in the table below.
All the drawings show one detail that is often drawn incorrectly. The straight part of the vertical track is shorter than the leaf: at DoorHan it ends 300–550 mm below the top of the opening, followed by the radius. The leaf of a closed door is 50–250 mm taller than the opening and presses against the lintel with its top seal. Therefore, in the closed position the top section already rests with its rollers on the curve, and when opening it immediately moves back rather than rising vertically.
Standard lift
The most common option. The vertical tracks turn through a radius into the horizontal ones; the shaft with the springs is above the opening, at the wall, above the horizontal tracks. The minimum headroom depends on the track radius: for DoorHan industrial doors it is 420 mm with a 381 mm radius and 350 mm with a 305 mm radius. Alutech Prestige garage doors need only 210 mm for standard installation. The drum is cylindrical, with a winding diameter of about 100 mm. The spring makes H/(π·Dd) turns plus pre-tension: 7–8 turns for a 2.3–2.5 m opening. The load drops almost linearly along the door travel, and a plain spring matches it well.
Low headroom
For buildings with little space above the opening. The top section is guided along a separate, additional horizontal track so that the turn fits into a small height.
Front-mounted shaft, above the opening. The springs and drums are the same as for a standard lift. DoorHan: headroom from 230 mm (260 mm with an operator), in the RKTN version from 160 mm. Alutech ProPlus: from 250 mm, with the second mounting variant (“type 2”) from 260 mm.
Rear-mounted shaft, at the end of the horizontal tracks. The cables run from the drums forward along the tracks over pulleys to the bottom brackets. DoorHan: headroom 150 mm, with a ceiling-mounted operator 180 mm. The cables are longer, there are more pulleys, and maintenance is less convenient: you have to reach the springs deep inside the building.
With extension springs — the lowest option for light garage doors: from 100 mm at DoorHan and Alutech. There is no torsion shaft at all: the springs stand vertically in the side columns, and the cable runs from the bottom corner of the leaf over a pulley at the top of the column. This option is not used for heavy and industrial doors.
The cable take-up with low headroom is the same as with a standard lift, so the number of spring turns hardly changes.
High lift
When there is plenty of space above the opening, the vertical tracks continue above the opening. The leaf first rises vertically by the high-lift height HL and then turns to horizontal. This way the door goes right up under the ceiling and frees space for an overhead crane, a lift or racking. At DoorHan, high lift starts with headroom over 520 mm, and HL by default equals the headroom minus 330 mm. Alutech Prestige high-lift installation with a top shaft starts from 500 mm.
The shaft is placed either at the top, above the horizontal tracks, or at the bottom — on brackets behind the vertical track, just above the opening. A bottom shaft is easier to service from a ladder, but DoorHan allows it only with large headroom: from 1600 mm and HL from 1330 mm.
While the leaf travels vertically, its whole weight hangs on the cables and the torque does not drop. Therefore high lift requires a special drum with cylindrical and conical parts: the variable winding radius adjusts the lever arm to the changing spring torque. There are more turns: each metre of HL with a drum of about 100 mm adds roughly 3 turns. The springs come out longer, and for large HL they are more often made of thick wire with a large diameter.
Vertical lift
The leaf rises strictly vertically along the wall, without horizontal tracks. DoorHan requires headroom greater than the opening height plus 500 mm with a top shaft, and greater than H + 120 mm with a bottom shaft. It is used in tall workshops and hangars where the ceiling is taken up by an overhead crane or utilities. The leaf weight acts on the cables over the whole travel, so the drum is conical, of large diameter, and the springs are the heaviest, with the largest number of turns (fig. 5, right).
Roof-pitch lift
The horizontal tracks rise at an angle, following the roof slope. DoorHan makes pitches from 5 to 65° in 5° steps: standard roof-pitch with headroom over 500 mm, high-lift roof-pitch with HL from 330 mm, and with a bottom shaft with HL from 1330 mm. The shaft is at the top, at the start of the incline, or at the bottom. Part of the leaf weight on the inclined section continues to hang on the cables, so the load drops more slowly than with a standard lift. Drums and springs are selected according to the pitch angle; with a steep slope, the calculation approaches that of a high lift.
Alutech ProPlus also has a low-headroom roof-pitch installation, from 275 mm: this is a low headroom lift with a rear shaft, except that the tracks follow the slope. The shaft is at the upper end of the inclined tracks, and the cables run from it down along the tracks over pulleys.
Twin-shaft system
Heavy industrial doors need so many springs that they do not fit on one shaft. Then two torsion shafts, one above the other, are installed, each with its own springs and drums. Alutech ProPlus offers a twin-shaft system for almost all lift types: standard, high, roof-pitch and vertical. The shafts are placed in the same positions as a single shaft — at the top by the wall or at the bottom on brackets behind the track.
The second shaft needs space: the lintel for a standard lift grows from 410 to 840 mm, for a high lift with shafts at the top from 900 to 1275 mm, and with shafts at the bottom from 1795 to 2100 mm. Each shaft balances its own part of the weight, so the springs on both shafts are wound equally and according to the door documentation. They must also be replaced as a set from both shafts.
Fig. 7. Twin-shaft balancing system per the Alutech ProPlus technical catalog. The lintel for two shafts is noticeably larger than for one.
Minimum headroom (for Alutech, the lintel height) in millimetres. H and RM — opening height, HL — high-lift height, R — track radius. Sources: DoorHan technical solutions catalog, Alutech Prestige and ProPlus technical catalog.
How to determine the lift type on site. Measure the opening height and the headroom to the lowest point above the future door path. Compare with the table. Then check the depth: the horizontal tracks extend into the building by the opening height plus 0.5–1 m, and there must be no obstructions along this length. When replacing springs on existing doors, the lift type can be seen from the shape of the tracks and from the drums: high and vertical lifts have stepped or conical drums.
Hörmann lift types
Hörmann designates the hardware type (Beschlagsart) with a letter code, and this code is on the door data plate. The first letter is the basic type: N — standard (Normal), L — low headroom (Niedrigsturz), H — high lift (höhergeführt), V — vertical. The second letter specifies it further: A — shaft raised higher, U — shaft at the bottom, D — following the roof pitch (Dachfolge), G — steep track, S and K — track with two 45° bends or with bends matching the angles of a specific building. Industrial doors have more than twenty types; garage doors have four: N, H, L and Z (extension springs in the side columns).
Hörmann installation data also confirm what is shown in the drawings above: with standard hardware, the track bend starts 200 mm below the top of the opening (RM − 200).
Fig. 7a. Types not found in the DoorHan and Alutech catalogs, per Hörmann installation data for industrial doors. Hörmann makes the types with 2×45° bends and the vertical type with a radius run-off only after a technical review at the factory.
Hörmann code
What it is
Equivalent in this article
Min. headroom, mm
N
Normal-Beschlag
standard
390 / 440 / 550 depending on hardware size; two shafts — 760
NA
N with raised shaft
standard
400 / 450
ND
N following the roof pitch
roof-pitch
390 / 440 / 550
NH
N with a small high lift
between standard and high lift
610–900
NS, NK
N with two 2×45° bends (NK — angles to suit the building)
—
390 / 440
GD, GS
NH with pitch up to 27° / NH with double radius
high-lift roof-pitch
610–790
L, LD
low headroom (Niedrigsturz) / same with pitch
low headroom, rear shaft; low-headroom roof-pitch
200
H
high lift (höhergeführt)
high lift
880–950
HA
H with raised shaft
high lift
890
HD
H following the roof pitch
high-lift roof-pitch
880–950
HG
H with steep track, for doors at loading docks
—
to order
HU
H with bottom shaft
high lift, bottom shaft
1760
RD, RG
HU with pitch / HU with steep track
high-lift roof-pitch, bottom shaft
1760
HS, HK, RS, RK
H or HU with 2×45° bends
—
subject to factory review
V
vertical
vertical
RM + 500…635
VA
V with raised shaft
vertical
RM + 510
VU, WG
V with bottom shaft / same with steep track
vertical, bottom shaft
RM + 350
VS, WS
V or VU where the track runs off along a radius at the top if there is not enough height
—
subject to factory review
HP, VP
high / vertical with two shafts, top and bottom (Parcel doors only)
twin-shaft system
HP: 1930–1960
Source: Hörmann, Einbaudaten Industrie-Sectionaltore, 03.2017, pp. 8–9 and 52. RM — opening height (Rastermaß). Headroom depends on the hardware size (N1–N3, H4–H8, etc.), which is selected according to the door weight and size.
06Cycle life: why springs break
A broken spring is one of the most common door failures. Every raising and lowering is a cycle of winding and unwinding. Fatigue accumulates in the metal, a microcrack appears on the wire surface, and the spring breaks, usually with a loud bang. Most often the fracture is a few coils from the plug, where the stress is higher.
A spring is a consumable, like brake pads in a car. Its cycle life is set during the calculation: for residential doors usually 10,000–25,000 cycles, for industrial doors 50,000–100,000 and more. How many years this means depends on how often the door is opened:
Door location
Cycles per day
Cycles per year
10,000
25,000
50,000
100,000
Private garage, one car
2
730
13 years
34 years
—
—
Family garage, entry through the garage
6
2,200
4.5 years
11 years
23 years
—
Car service, car wash
30
11,000
11 months
2.3 years
4.5 years
9 years
Warehouse, logistics
60
22,000
5 months
1.1 years
2.3 years
4.5 years
100-space parking garage
200
73,000
7 weeks
4 months
8 months
1.4 years
This leads to several practical rules:
Replace springs in pairs, even if only one has broken. Both have gone through the same number of cycles, and the second one usually breaks within a few weeks. That means a second technician visit and a second door downtime.
Keep a spare set for frequently used doors: in parking garages, warehouses, service centers. Springs are often made to order, and delivery can take several weeks.
When replacing, you can specify a higher cycle life than the factory one, if there is room on the shaft for a longer spring. Springs for 50,000 cycles cost more, but in a parking garage they pay for themselves with the very first replacement avoided.
An example of a factory rule: Hörmann designs the torsion springs of industrial doors with standard, low-headroom and roof-pitch hardware (N, ND, NS, NK, NA, NH, GD, GS, L, LD) for at least 25,000 closings, and with high-lift and vertical hardware for at least 50,000.
Besides fatigue, cycle life is reduced by corrosion (rust on the surface is a ready-made crack initiation site), incorrect winding (an overwound spring works at increased stress), dry friction between the coils and imbalance, in which the operator pulls the door in jerks.
07Material, manufacturing, coatings
Wire
Springs are wound from cold-drawn carbon spring wire. Common standards:
EN 10270-1 (formerly DIN 17223) — patented cold-drawn wire; for door springs, grades SH and DH.
EN 10270-2 — oil-tempered wire. It is widely used in North America.
GOST 9389 — Russian carbon spring wire.
The strength of spring wire depends on its diameter: the thicker the wire, the lower its tensile strength. For diameters of 5–11 mm it is roughly 1500–1950 N/mm². Not only strength matters, but also fatigue resistance: steel cleanliness, absence of surface defects and of a decarburized layer.
How a spring is made
Preparation. The wire arrives in coils already at the required diameter and with factory heat treatment.
Coiling. A machine winds the wire onto a mandrel of a given diameter and in a given direction, coil to coil, without a gap.
Stress-relief tempering. The spring is heated to about 250–300 °C. This relieves the internal stresses after coiling and stabilizes the dimensions.
Coating. Galvanizing (or coiling from pre-galvanized wire), primer, powder coating.
Marking and inspection. Dimension check, applying the color stripe along the spring, and assembly with the plugs.
Protective coatings
Zinc (usually 15–25 µm) protects the steel electrochemically: even at a scratch, it is the zinc that corrodes, not the wire.
Primer bonds the zinc and the finish coat.
Powder paint (up to 80 µm) protects against moisture and mechanical damage; a common color is gray.
A multilayer coating is needed for doors of car washes, coastal areas and unheated warehouses. In a dry heated garage, zinc is enough.
08How to measure a spring for replacement
The easiest way is to order springs by the door serial number from the data plate: the parameters of manufactured doors are stored in the manufacturer's database, and the dealer will select the original springs. If there is no data plate, the spring is measured.
Winding direction and stripe. Note on which side of the bracket each spring is and what color its stripe or plug is.
Inside diameter. Measure the outside diameter and subtract two wire thicknesses. High accuracy is not needed: choose the nearest value of the series 45, 50, 67, 95, 152 mm.
Wire diameter. With a caliper on a single coil, but this way is more reliable: measure the length of 10 or 20 closed coils with a tape measure and divide by their number. An error of 0.5 mm in the wire changes the rate by 25–30%, so count carefully.
Length. Measure an unwound spring: a wound one is longer by about d for each turn. Put a broken spring together from its two pieces. Check with the supplier whether the length is given with or without the plugs.
Plug type and insert. Take photos of the plugs. If the old spring had a plastic insert, the new one must have an insert too.
Number of winding turns. If you have the door documentation, take it from there. If not, it is calculated from the opening height and the drum (section 4).
With this data, contact the door dealer or a spring manufacturer.
09Winding and safety
Danger. A wound spring stores a lot of energy. In the example from section 4 (80 kg, 8.3 turns) it is about 1000 J — like a 100 kg weight dropped from a height of one metre. A winding bar that slips out, or a plug with under-tightened set screws, unwinds instantly and injures hands and head. Work on springs must be done by a trained installer.
Winding procedure
The door is closed. The leaf is secured, for example with a clamp on the track above a roller, so that it does not rise during winding.
The cables are fitted into the drums and taken up without slack, and the drums are fixed on the shaft. Both sides must be tensioned equally, otherwise the leaf will be skewed.
The spring is wound through the holes of the winding plug with two winding bars of suitable diameter, 40–50 cm long. One bar is always kept in a hole while the other is being repositioned. A screwdriver, rebar or a rod of the wrong diameter will not do: they pop out of the hole under load.
It is more convenient and safer to use a winder — a tool that holds the spring and turns the plug without switching winding bars (for example, the TORSMASTER winder).
The number of turns is taken from the documentation and counted by the stripe (fig. 8). After winding, the set screws of the plug are tightened to the torque specified by the manufacturer (at DoorHan — no more than 15 N·m), and only then is the winding bar removed.
The leaf is released and the balance is checked: a door raised to about one metre should stay in place. If it goes down, add a quarter turn to each spring; if it goes up, reduce the winding.
When wound, the spring gets longer by about one wire diameter per turn, and its inside diameter decreases: the number of coils increases by the number of turns. Therefore there must be free travel along the shaft between the plugs, and the winding plug is tightened on the shaft only after winding.
Fig. 8. The stripe makes it easy to count turns: the number of helix turns the stripe has twisted into equals the number of turns made. On both springs of the same shaft, the helices should come out the same.
10Maintenance and signs of failure
Every six months
Check the balance: disconnect the operator, raise the door by one metre and let go.
Lubricate the springs with a thin coat of oil along their whole length. This reduces friction between the coils, noise and corrosion.
Inspect the cables (frayed strands, rust), the drums and the bottom brackets.
Check that the set screws of the plugs and drums are tight.
Signs of a spring problem
A 5–10 cm gap between coils is visible on the spring — the spring has broken.
The door has become heavy to lift by hand, the operator stops or its force protection trips.
The door lowers by itself from a middle position: the springs have weakened or there is not enough winding.
The door rises by itself, and the cables sag in the open position: the springs are overwound.
The leaf rises skewed: the left and right springs are wound differently, or a cable has come off a drum.
The most common mistake in repairs is to wind the remaining intact spring harder to “pull” the door with one spring. It gets overloaded and breaks quickly, and a door without spring break protection can fall. The second mistake is to install springs chosen by eye: the door seems to open, but the operator works at its limit, and the cycle life of the springs and the operator is cut many times over.
In brief
Springs counterbalance the weight of the leaf; a properly balanced door stays put in any position.
A spring is described by its inside diameter, wire diameter, length and winding direction.
The spring torque must equal the leaf weight multiplied by the drum radius; the number of turns is set by the opening height.
The same door can be balanced with different springs; thicker and longer means a longer cycle life.
The lift type determines the headroom, the shaft position, the drum shape and the load on the springs.
Springs are consumables: replace them in pairs, and have them wound by a trained technician with the right tools.
The calculation examples in this article are for illustration and are based on general strength-of-materials formulas. To order and wind springs, use the door documentation and the manufacturer's data.